ACS 653, ACS 663 Service Manual
SP00D00624 2021-04-08 Robert Bosch GmbH
106
Plumbing and Mechanical


HS and LS inlet solenoids are activated to equalize high and low sides of system being serviced. Unit checks low-side
transducer for rise in vacuum. If the unit sees a pressure rise within 5 minutes time, the vacuum leak test will fail..