1.20 Fault Analysis
1. Press and hold the [5] key until two beeps are
heard.
2. Zone Indicators display FAULT conditions
(see Table 7).
3. Press [#] key to exit.
Table 7: Fault Analysis Conditions
Zone
LED
Fault Condition Description
1 System Fault
Press and hold button [1] to
determine fault.
1 = Battery Fail
2 = Date/Time
3 = RF Rx Jamming
RF Rx Tamper
RF Rx Comm’s Fail
4 = Horn Speaker Fail
5 = Telephone Line Fail
6 = E2 Fail
7 = Fuse Fail
8 = AC Fail
2 RF Low Battery Press and hold button [2] to
determine fault.
Displays zones (1 to 8) that register
RF Low Battery.
3 Zone Tamper Press and hold button [3] to
determine fault.
Displays zones (1 to 8) that register
Zone Tamper.
4 Sensor Watch Press and hold button [4] to
determine fault.
Displays zones (1 to 8) that register
Zone Sensor Watch
5 RF Sensor
Watch
Press and hold button [5] to
determine fault.
Displays zones (1 to 8) that register
Zone RF Sensor Watch
6 Communication
Fail
Press and hold button [6] to
determine fault.
1 = Receiver 1 Fail (Dialler)
2 = Receiver 2 Fail (Dialler)
1.21 Modem Call (Alarm Link)
Press and hold the [6] key until two beeps are
heard.
1.22 Latching Outputs (Reset)
Press and hold the [7] key until two beeps are
heard.
1.23 Codepad ID/Buzzer Tone
1. Press and hold the [8] key until the desired
buzzer tone is reached.
If the system is partitioned (CC488 only), the
codepad displays a number identifying which
area the codepad belongs (see Table 8).
2. Press the [#] key to exit.
Table 8: Codepad ID/Buzzer Tone
Zone LED Codepad Assignment
1 Area 1
2 Area 2
7 Master Partitioned Codepad
1.24 Test Report
Press and hold the [9] key until two beeps are
heard.
1.25 Speaker Test
Press and hold the [1] key until two beeps are
heard. The speaker sounds for two seconds.
1.26 Bell Test
Press and hold the [2] key until two beeps are
heard. The piezo sounds for two seconds.
1.27 Strobe Test (Toggle On/Off)
Press and hold the [3] key until three beeps are
heard to turn the strobe on.
Or
Press and hold the [3] key until two beeps are
heard to turn the strobe off.
1.28 Telco Arm Sequence (Call
Forward On)
1. Enter your four character Installer Code or
Master Code followed by [3] and the [#] key
(for example, [1 2 3 4 3 #]).
2. Press [1] followed by the [#] key.
3. Enter the Call Forward On sequence.
4. Press the [#] key to exit.
1.29 Telco Disarm Sequence (Call
Forward Off)
1. Enter your four character Installer Code or
Master Code followed by [3] and the [#] key
(for example, [1 2 3 4 3 #]).
2. Press [2] followed by the [#] key.
3. Enter the Call Forward Off sequence.
4. Press the [#] key to exit.