CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 13
Bosch Security Systems | 6/04 | 4998152446B
2.4 Day Alarm Zones
Location
265
Default
0
1 Zone 1
2 Zone 2
4 Zone 3
8 Zone 4
2.5 EOL Resistor Value
Location
266
0 No EOL
1 1k
2 1k5
3 2k2
4 3k3
5 3k9
6 4k7
7 5k6
8 6k8
9 10k
10 12k
11 22k
12 Reserved
13 Reserved
14 Split EOL (3k3/6k8 with tamper 1k)
15 Split EOL (3k3/6k8)
2.6 Zone Programming
2.6.1 Zone Defaults
Location
267 to 322
Location Default
Zone #01 (Default = Delay-1)
Zone Type 267 2
Zone Pulse Count 268 0
Zone Pulse Count Time 269 0
Zone Options 1 270 1
Zone Options 2 271 14
Report Code 272 1
Dialler Options 273 1
Zone #02 (Default = Handover)
Zone Type 274 1
Zone Pulse Count 275 0
Zone Pulse Count Time 276 0
Zone Options 1 277 1
Zone Options 2 278 14
Report Code 279 1
Dialler Options 280 1
Zone #03 (Default = Handover)
Zone Type 281 1
Zone Pulse Count 282 0
Zone Pulse Count Time 283 0
Zone Options 1 284 1
Zone Options 2 285 14
Report Code 286 1
Dialler Options 287 1
2.6.1 Zone Defaults (continued)
Location
267 to 322
Zone #04 (Default = Handover)
Zone Type 288 1
Zone Pulse Count 289 0
Zone Pulse Count Time 290 0
Zone Options 1 291 1
Zone Options 2 292 14
Report Code 293 1
Dialler Options 294 1
Zone #05 (Default = Instant)
Zone Type 295 0
Zone Pulse Count 296 0
Zone Pulse Count Time 297 0
Zone Options 1 298 1
Zone Options 2 299 14
Report Code 300 1
Dialler Options 301 1
Zone #06 (Default = Instant)
Zone Type 302 0
Zone Pulse Count 303 0
Zone Pulse Count Time 304 0
Zone Options 1 305 1
Zone Options 2 306 14
Report Code 307 1
Dialler Options 308 1
Zone #07 (Default = Instant)
Zone Type 309 0
Zone Pulse Count 310 0
Zone Pulse Count Time 311 0
Zone Options 1 312 1
Zone Options 2 313 14
Report Code 314 1
Dialler Options 315 1
Zone #08 (Default = 24 hr. Tamper)
Zone Type 316 9
Zone Pulse Count 317 0
Zone Pulse Count Time 318 0
Zone Options 1 319 1
Zone Options 2 320 12
Report Code 321 1
Dialler Options 322 1