CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 14
Bosch Security Systems | 6/04 | 4998152446B
2.6.2 Zone Types
Zone Type Description
0 Instant
1 Handover
2 Delay-1
3 Delay-2
4 Reserved
5 Reserved
6 24 hr. Medical
7 24 hr. Panic
8 24 hr. Hold-up
9 24 hr. Tamper
10 Reserved
11 Keyswitch
12 24 hr. Burglary
13 24 hr. Fire
14 Chime
15 Not Used
2.6.3 Zone Pulse Count
Use the pulse count to program how many pulses
(0 to 15) need to be registered within the pulse
count time to activate an alarm.
2.6.4 Zone Pulse Count Time
Option 20 ms Loop
Response Time
Option 150 ms Loop
Response Time
0 0.5 sec. 8 20 sec.
1 1 sec. 9 30 sec.
2 2 sec. 10 40 sec.
3 3 sec. 11 50 sec.
4 4 sec. 12 60 sec.
5 5 sec. 13 90 sec.
6 10 sec. 14 120 sec.
7 15 sec. 15 200 sec.
2.6.5 Zone Options 1
Option Description
1 Lockout siren/dialler
2 Delay Alarm report
4 Silent alarm
8 Sensor watch
2.6.6 Zone Options 2
Option Group
1 Isolated in STAY Mode 1
2 Zone isolation allowed
4 Forces arming allowed
8 Zone Restore Report allowed
2.6.7 Zone Dialler Options
Option Description
0 No zone reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.6.8 Keyswitch Zone Options
The keyswitch zone options replace Zone Options
1 only for the zones that were programmed to
operate as a keyswitch zone.
Option Description
0 Latching arm and disarm in AWAY Mode
1 Latching arm in AWAY Mode
2 Latching disarm from AWAY Mode or STAY Mode
4 Latching arm and disarm in STAY Mode
5 Latching arm in STAY Mode
6 Latching disarm from STAY Mode
8 Momentary arm and disarm in AWAY Mode
9 Momentary arm in AWAY Mode
10 Momentary disarm from AWAY Mode or STAY
mode
12 Momentary arm and disarm in STAY Mode
13 Momentary arm in STAY Mode
14 Momentary disarm from STAY Mode
2.7 Swinger Programming
2.7.1 Swinger Shutdown Count For Siren
Location
323
Default
3
0 Unlimited
1 to 15 Number of times siren operates until lockout
2.7.2 Swinger Shutdown Count For Dialler
Location
324
Default
6
0 Unlimited
1 to 15 Number of times dialler operates until lockout
2.8 Zone Status Programming
2.8.1 Zone Status – Zone Tamper Report
Location
325 to 326
Location Default
Zone Tamper Report 325 0
Zone Tamper Restore Report 326 0
2.8.2 Zone Status – Walk Test Report
Location
327 to 328
Location Default
Walk Test Start Report 327 0
Walk Test End Report 328 0
2.8.3 Zone Status – Bypass Report
Location
329 to 330
Location Default
Zone Bypass Report 329 9
Zone Bypass Restore Report 330 8
2.8.4 Zone Status – Trouble Report
Location
331 to 332
Location Default
Zone Trouble Report 331 2
Zone Trouble Restore Report 332 3