CC488 | Quick Reference Guide | 1.0 Overview EN | 7
Bosch Security Systems | 6/04 | 4998152446B
Table 2: Codepad Indicators
Data
Value
Zone 1
Indicator
Zone 2
Indicator
Zone 3
Indicator
Zone 4
Indicator
Zone 5
Indicator
Zone 6
Indicator
Zone 7
Indicator
Zone 8
Indicator
MAINS
Indicator
0
1 X
2 X
3 X
4 X
5 X
6 X
7 X
8 X
9 X X
10 X
11 X X
12 X X
13 X X
14 X X
15 X X
1.4 Programming Option Bits
Use option bits to program any combination of the
four different options in one location by adding
the options together. Programming a zero disables
all four options.
Example
If at LOCATION 177 you only want options 1, 2,
and 4, add the numbers together and the total is
the number to be programmed. The number to be
programmed is 7 (1 + 2 + 4 = 7).
Table 3: Programming Option Bits
Option Description
1 Dialler reporting functions allowed
2 Remote arming using telephone allowed
4 Answering machine bypass only when armed
8 Use bell 103 for FSK format
(Disabled = CCITT V21)
1.5 Installer’s Programming
Commands
Installer Programming Commands, displayed in
Table 4, can only be used when you enter
Installer’s Programming Mode. Enter the
command followed by the [#] key.
Table 4: Installer’s Programming Commands
Command Description
958 Enable/disable zone status (hand held programmer
required).
959 Test programming key.
960 Exit Installer’s Programming Mode.
961 Default system back to factory settings.
962 Copy panel memory to programming key.
963 Copy programming key to panel memory.
964 Erase programming key.
965 Default system for domestic dialling format.
966 Enable/disable automatic stepping of locations
when programming.
999 Display software version (hand held programmer
required).

Table of Contents