CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 12
Bosch Security Systems | 6/04 | 4998152446B
2.1.17 Telephone Line Fail Options
Location
176
Default
0
1 Display FAULT Indicator when telephone line fails
2 Sound alarm when system is armed
4 Sound alarm when system is disarmed
Options 2 and 4 must be used in conjunction with Option
1 (for example, program 1, 3, 5, or 7)
2.1.18 Dialler Options 1
Location
177
1 Dialler reporting functions allowed
2 Remote arming by telephone allowed
4 Answering machine bypass only when armed
8 Use Bell 103 for FSK format (Disabled = CCITT V21)
2.1.19 Dialler Options 2
Location
178
Default
0
1 Open/Close Reports only if previous alarm
2 Open/Close Reports for STAY Mode 1 and STAY
Mode 2
4 Delay siren until transmission complete
8 Extend handshake wait time from 30 to 55 sec.
2.1.20 Dialler Options 3
Location
179
Default
0
1 Set DTMP dialling pulses to 1 digit/sec.
2 Lockout telephone line fail alarm (V1.03+)
4 Change Decadic dialling to 60/40
8 Reserved
2.1.21 Dialler Options 3 (V1.04+)
Location
179
1 Set DTMP dialling pulses to 1 digit/sec.
2 Lockout telephone line fail alarm (V1.03+)
4 Change Decadic dialling to 60/40
8 External modem module (CC811) required for FSK
(V1.09+)
2.1.22 Alarm Link Options
Location
180
1 Upload/download allowed
2 Call back phone number required for upload/download
4 Exit upload/download connection on alarm
8 External modem module (CC811) required for alarm link
2.2 Installer Code
Location
181 to 184
Location Default
181 1
182 2
183 3
184 4
2.3 User Code Programming
2.3.1 User Codes
Location
185 to 264
Location Default
User #01 185 2
186 5
187 8
188 0
189 (Authority Level) 10
User #02 190 to 193 15
194 2
User #03 195 to 198 15
199 (Authority Level) 2
User #04 200 to 203 15
204 (Authority Level) 2
User #05 205 to 208 15
209 (Authority Level) 2
User #06 210 to 213 15
214 (Authority Level) 2
User #07 215 to 218 15
219 (Authority Level) 2
User #08 220 0
221 to 223 15
224 (Authority Level) 3
RF User #09 225 to 228 15
229 (Authority Level) 2
RF User #10 230 to 233 15
234 (Authority Level) 2
RF User #11 235 to 238 15
239 (Authority Level) 2
RF User #12 240 to 243 15
244 (Authority Level) 2
RF User #13 245 to 248 15
249 (Authority Level) 2
RF User #14 250 to 253 15
254 (Authority Level) 2
RF User #15 255 to 258 15
259 (Authority Level) 2
RF User #16 260 to 263 15
264 (Authority Level) 2
2.3.2 Authority Levels
Authority
Levels
Description
0 Arm/Disarm
1 Arm Only
2 Arm/Disarm and Open/Close Reports
3 Arm Only and Close Reports
4 Arm/Disarm and Code Required to Isolate
6 Arm/Disarm and Open/Close Reports and Code
Required to Isolate
8 Master Code and Arm/Disarm
10 Master Code and Arm/Disarm and Open/Close
Reports
12 Master Code and Arm/Disarm and Code
Required to Isolate
14 Master Code and Arm/Disarm and Code
Required to Isolate and Open/Close Reports