CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 15
Bosch Security Systems | 6/04 | 4998152446B
2.8.5 Zone Status – Sensor Watch Report
Location
333 to 334
Location Default
Sensor Watch Report 333 4
Sensor Watch Restore Reprot 334 5
2.8.6 Zone Status – Alarm Restore Code
Location
335
Default
14
2.8.7 Zone Status Reporting Options
Location
336
0 No zone status reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.9 RF Programming
2.9.1 RF Supervision Time
Location
337
Default
0
Increments of 6 hrs. (0 to 90 hrs.)
2.9.2 RF Low Battery Report
Location
338 to 339
Location Default
RF Low Battery Report 338 6
RF Low Battery Restore Report 339 8
2.9.3 RF Receiver Trouble Report
Location
340 to 341
Location Default
RF Receiver Trouble Report
(tens digit)
340 7
RF Receiver Trouble Report
(units digit)
341 9
2.9.4 RF Receiver Trouble Restore Report
Location
342 to 343
Location Default
RF Receiver Trouble Restore Report
(tens digit)
342 7
RF Receiver Trouble Restore Report
(units digit)
343 11
2.9.5 RF Dialler Options
Location
344
0 No Zone Status Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.10 Report Programming
2.10.1 Open/Close Reports
Location
345 to 346
Location Default
Open Report 345 11
Close Report 346 12
2.10.2 Open/Close Reporting Options
Location
347
0 No Open/Close Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.10.3 Codepad Duress Report
Location
348
Default
6
2.10.4 Codepad Panic Report
Location
349 to 350
Location Default
Tens digit 349 7
Units digit 350 15
2.10.5 Codepad Fire Report
Location
351 to 352
Location Default
Tens digit 351 7
Units digit 352 14
2.10.6 Codepad Medical Report
Location
353 to 354
Location Default
Tens digit 353 7
Units digit 354 13
2.10.7 Codepad Reporting Options
Location
355
0 No Codepad Alarm Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.11 System Status Programming
2.11.1 System Status – Fuse Fail Report
Location
356 to 357
Location Default
Tens digit 356 10
Units digit 357 3
2.11.2 System Status – Fuse Fail Restore
Report
Location
358 to 359
Location Default
Tens digit 358 10
Units digit 359 8
2.11.3 System Status – AC Fail Report
Location
360 to 361
Location Default
Tens digit 360 10
Units digit 361 2