EasyManua.ls Logo

Bosch CC488 - 2.10 Report Programming

Bosch CC488
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 15
Bosch Security Systems | 6/04 | 4998152446B
2.8.5 Zone Status – Sensor Watch Report
Location
333 to 334
Location Default
Sensor Watch Report 333 4
Sensor Watch Restore Reprot 334 5
2.8.6 Zone Status – Alarm Restore Code
Location
335
Default
14
2.8.7 Zone Status Reporting Options
Location
336
0 No zone status reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.9 RF Programming
2.9.1 RF Supervision Time
Location
337
Default
0
Increments of 6 hrs. (0 to 90 hrs.)
2.9.2 RF Low Battery Report
Location
338 to 339
Location Default
RF Low Battery Report 338 6
RF Low Battery Restore Report 339 8
2.9.3 RF Receiver Trouble Report
Location
340 to 341
Location Default
RF Receiver Trouble Report
(tens digit)
340 7
RF Receiver Trouble Report
(units digit)
341 9
2.9.4 RF Receiver Trouble Restore Report
Location
342 to 343
Location Default
RF Receiver Trouble Restore Report
(tens digit)
342 7
RF Receiver Trouble Restore Report
(units digit)
343 11
2.9.5 RF Dialler Options
Location
344
0 No Zone Status Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.10 Report Programming
2.10.1 Open/Close Reports
Location
345 to 346
Location Default
Open Report 345 11
Close Report 346 12
2.10.2 Open/Close Reporting Options
Location
347
0 No Open/Close Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.10.3 Codepad Duress Report
Location
348
Default
6
2.10.4 Codepad Panic Report
Location
349 to 350
Location Default
Tens digit 349 7
Units digit 350 15
2.10.5 Codepad Fire Report
Location
351 to 352
Location Default
Tens digit 351 7
Units digit 352 14
2.10.6 Codepad Medical Report
Location
353 to 354
Location Default
Tens digit 353 7
Units digit 354 13
2.10.7 Codepad Reporting Options
Location
355
0 No Codepad Alarm Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.11 System Status Programming
2.11.1 System Status – Fuse Fail Report
Location
356 to 357
Location Default
Tens digit 356 10
Units digit 357 3
2.11.2 System Status – Fuse Fail Restore
Report
Location
358 to 359
Location Default
Tens digit 358 10
Units digit 359 8
2.11.3 System Status – AC Fail Report
Location
360 to 361
Location Default
Tens digit 360 10
Units digit 361 2