Flexible Automation
System introduction CL400
1-7
1070 072 143-101
Specifications CL400
Interference emission
D hard emission none
D radio interference suppression
housing to DIN EN 500812
Class A
D Frequency 30 to 230 MHz limit
value 30 dB (MV/m) in 30 m
D Frequency 230 to 1000 MHz
limit value 37 dB (MV/m) in
30 m
D ZZF number no ZZF number required
Insulation test voltage
D NT1, NT2 and NT3 D for U
E
= 115 V
1060 V
1500 V-
D for U
E
= 230 V
1780 V
2500 V-
D all other modules 350 V
500 V-
Mechanical strength
D sinusoidal oscillations in all 3
axes to DIN EN 611312
D 10 Hz to 57 Hz
D 0.0375 mm amplitude con
stant
D 0.075 mm amplitude occa
sional
D 57 Hz to 150 Hz
D 0.5 g constant
D 1 g occasional
D impacts in all 3 axes to
DIN EN 611312
11 ms semisinusoidal 15 g
Corrosion, chemical resistance The surrounding air must be free
from high levels of acid, lye, corros
ive materials, salts, metal vapours,
or other conductive impurities.
Level of contamination to
VDE 0110 part 1
2
The immediate environment must
be free from dust. Housing and in
stallation compartments (in which
the subrack is housed) must meet
protection standard IP 54.