D7212GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 47
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
CC# Scope
Default: Refer to the program record sheet
Selection:
Panel Wide, Custom, No Keypad,
Area, and Account
Panel
Wide
A panel-wide keypad can view
information and perform Arming and
Disarming functions for all areas in
the control panel. A panel-wide
keypad can cross account
boundaries. This is normally used
with a master area.
Account An Account keypad can view
information, and perform Arming and
Disarming functions for all areas with
the same A# Account Number, in
Area Parameters. This is normally
used for an associate area.
Area An area keypad is restricted to
viewing information and Arming or
Disarming functions for the area to
which it is assigned.
Custom A custom keypad has no keypad
restrictions. This option is not
available through Keypad
Programming.
No
Keypad
No keypad installed at this address.
CALL FOR SERVICE display shows,
indicating the control panel is not
polling this address.
This program item is used to define the areas
affected when an arming command is executed on
this keypad, the areas this keypad can view, and the
areas to which this keypad can move.
In applications where keypads include
more than one area, active alarms in
remote areas must be acknowledged
before arming or disarming the local area.
The following prompt is visible only when
you program CC## Scope to Custom. If
you change the keypad scope selection
to Custom from Panel Wide, Account, or
Area, the settings from the previous CC#
Scope selection become the default
settings for the custom parameters in
CC# A1 [through A4] in Scope. Before
exiting a custom program, check each
area and ensure that it is enabled and
disabled correctly.
CC# A1[through A4] in Scope
Default: Refer to the preceding important
note
Selection:
Yes or No
Yes Include this area in the scope of this
keypad.
No Do not include this area in the scope
of this keypad.
Determines whether any of the four areas (Area 1 to
Area 4) are included in the scope of this keypad for
viewing status and arming or disarming the keypad.
Keypad Programming of CC# Scope
D1255
1. Refer to Figure 1 on page 6 to access Keypad
Programming and navigate to the COMMAND
CENTER option.
2. Press [ENT]. The CC NUM 1 – 8 option shows.
3. Enter the keypad number you wish to configure
and press [ENT]. The keypad reads CC#
SCOPE, and then the current configuration (for
example, PANEL WIDE).
4. To change the configuration, press [ENT] when
the current configuration shows, and then press
[NEXT] or [PREV] to scroll through the options,
as listed in CC# Scope on page 47.
5. When the keypad reads the desired configuration
option, press [ENT] to select it.
6. When the keypad reads PARAMETER SAVED,
your selection has been configured.
D1260
1. Refer to Figure 2 on page 7 to access Keypad
Programming and navigate to the Command
Center option.
2. Press [ENTER]. The CC Num 1 – 8 option
shows.
3. Enter the keypad number you wish to configure
and press [ENT]. The keypad reads CC# Scope,
and then the current configuration (for example,
Panel Wide).
4. To change the configuration, press the Edit
softkey, and then press the Next or Previous
sofkeys to scroll through the options, as listed in
CC# Scope on page 47.
5. When the keypad reads the desired configuration
option, Save to select it.
When the keypad reads Parameter Saved, your
selection has been configured.