D7212GV3 | Program Entry Guide | EN | 6
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
1.2.1 Local Keypad Programming
GV3 now offers a Local Keypad Programming menu with the Service Passcode only. It includes all custom
options. For a list of program items you can set using Keypad Programming, refer to Figure 1 on page 6 and
Figure 2 on page 7. To access the Keypad Programming menu, the Keypad Programming option must be set
to P (refer to 2.10.5 Configuration Authority on page 60), and all control panel areas must be disarmed.
Figure 1: D1255 Keypad Programming Menu and Page References
Refer to Phone #
on page 8.
Refer to Phone # Format
on page 9.
Refer to Enhanced Comm
on page 117.
Refer to R# Primary Device
on page 14 and R# Backup Device
on page
15
Refer to RPS Passcode
on page 27.
Refer to
RPS Phone #
on page 29.
Refer to RPS IP Address #
on page 115
.
Refer to RPS Port Number
on page 116.
Refer to
A# Area On on page 31 and
A# Account Number on page 31.
Refer to
CC# Scope on page 47 and
CC# Enhanced Command Center on
page 49.
Refer to
2.10.5 Configuration Authority
on page 60.
Refer to
P### Point Index
on page 91.