D7212GV3 | Program Entry Guide | 5.0 Schedules (Skeds) EN | 99
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Do not use a time of 23:59 as a window stop time
unless the window continues on the next day at
00:00. Fail to Close Reports are not sent, and the
Auto Close feature does not work for windows that
stop at 23:59.
Do not program a single window to cross the
midnight boundary. The window stop time must be
later than the window start time. To program a
window that effectively crosses the midnight
boundary, you must program two windows.
For example, to program windows for an area that
closes between 11:30 PM and 12:30 AM, five days a
week, use two windows as shown in Table 28.
Table 28: Programming Example: Using Two Closing Windows to Cross the Midnight Boundary
Open Close
W#
Day of Week
Early
Begin Start Stop
Early
Begin Start Stop
eXcept
On
Holiday
Holiday
Index Area(s)
1
S M T W T F S 22 : 00 23 : 30 23 : 59 Yes No 1 2 3 4 1 2 3 4 5 6 7 8
2
S M T W T F S 00 : 00 00 : 00 00 : 30 Yes No 1 2 3 4 1 2 3 4 5 6 7 8