EasyManua.ls Logo

Bosch D7212GV3 - Programming Example: Using Two Closing Windows to Cross the Midnight Boundary

Bosch D7212GV3
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D7212GV3 | Program Entry Guide | 5.0 Schedules (Skeds) EN | 99
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Do not use a time of 23:59 as a window stop time
unless the window continues on the next day at
00:00. Fail to Close Reports are not sent, and the
Auto Close feature does not work for windows that
stop at 23:59.
Do not program a single window to cross the
midnight boundary. The window stop time must be
later than the window start time. To program a
window that effectively crosses the midnight
boundary, you must program two windows.
For example, to program windows for an area that
closes between 11:30 PM and 12:30 AM, five days a
week, use two windows as shown in Table 28.
Table 28: Programming Example: Using Two Closing Windows to Cross the Midnight Boundary
Open Close
W#
Day of Week
Early
Begin Start Stop
Early
Begin Start Stop
eXcept
On
Holiday
Holiday
Index Area(s)
1
S M T W T F S 22 : 00 23 : 30 23 : 59 Yes No 1 2 3 4 1 2 3 4 5 6 7 8
2
S M T W T F S 00 : 00 00 : 00 00 : 30 Yes No 1 2 3 4 1 2 3 4 5 6 7 8