DS7400XiV4-EXP | Wireless Reference Guide | 5.0 Adding Keyfobs EN | 24
Bosch Security Systems | 6/05 | 4998154962B
5.7 On-Board Output Area (Partition) Assignment and Chirp Control (Optional)
You can assign outputs to follow the Option Key in one or all areas in the Output Area Assignment Addresses
2737 and 2738. You can also program outputs to “chirp” (a ½-second sounder output when the control panel is
armed, or two ½-second sounder outputs when the control panel is disarmed).
• Addresses: 2737 to 2738
• Data Digits:
• Data Digit 1: ____ (refer to Table 36; refer to Table 38 for defaults)
• Data Digit 2: ____ (refer to Table 36 for Address 2737 and Table 37 for Address 2738; refer to Table 38 for
defaults)
• Selections: 0 to 8
Table 36: Address 2737 to 2738, Data Digit 1,
and Address 2737 Data Digit 2
Select Option Value
Belongs to Area 1 0
Belongs to Area 2 1
Belongs to Area 3 2
Belongs to Area 4 3
Belongs to Area 5 4
Belongs to Area 6 5
Belongs to Area 7 6
Belongs to Area 8 7
Follows all Areas
8
Table 37: Address 2738, Data Digit 2
Keyfob Chirp Options Value
Chirp Disabled
0
Bell Output 1
Programmable Output 1 2
Programmable Output 2 3
Table 38: Address 2734 to 2738 Defaults
Output Address Default
Alarm 2737 DD1 8
Programmable Output 1 2737 DD2 8
Programmable Output 2 2738 DD1 8
Keyfob Chirp Options 2738 DD2 0
5.8 Program Output Functions to Follow the Keyfob Output Buttons (Optional)
You can assign output functions to off-board devices, multiplex (MUX) devices, and so on. Refer to Table 40 for
output function numbers and Program Addresses.
• Addresses: 2772 to 2841
• Data Digit:
• Data Digit 1: Must = *0 to follow wireless keyfob output buttons
• Data Digit 2: ____ (refer to Table 39)
• Selections: 0 to 4