DS7400XiV4-EXP | Wireless Reference Guide | 2.0 Programming the Control Panel EN | 6
Bosch Security Systems | 6/05 | 4998154962B
2.2.2 RF Receiver Jam Detection Level
The Jam Detection Level determines the level of
ambient RF noise at which a Jam Trouble is reported.
A higher programmed value requires a higher noise
level before a Jam Trouble is reported.
Adjusting this setting from its default value
can severely degrade control panel
performance. Do not adjust this setting
without first contacting Bosch Technical
Support.
Data Digit 1 configures the Jam Detection Level for
Receiver 1, and Data Digit 2 configures the Jam
Detection Level for Receiver 2.
Address: 4039
Data Digits:
Data Digit 1: ____ (default = 6)
Data Digit 2: ____ (default = 6)
Selections: 0 to 9; *0 to *5 (hexadecimal values
that display as A to F respectively at the keypads)