BoschRexrothAG, RE 92050-01-X-B2/2019-08-23
28 A4VSO Series 10, 11 and 30 | Axial piston variable pump
Dimensions, size 500
Dimensions [mm]
▼ Parallel keyed shaft DIN6885 ▼ Splined shaft DIN5480
P ‒ Ø80 AS 22×14×125 Z ‒ W80×3×25×9g
3
42
130
125
180
ø80
M20
1)2)3)
-0.2
+0.018
+0.002
Shaft key width 22
140
42
90
Ports Standard Size
3)
p
max abs
[bar]
4)
State
9)
B Working port (high-pressure series)
Fastening thread
SAE J518
6)
DIN 13
2 in
M20 × 2; 25 deep
400 O
B1 2. Working port (high-pressure series)
Fastening thread
SAE J518
6)
DIN 13
2 in
M20 × 2; 25 deep
400 X
8)
S Suction port SAE J518
6)
DIN 13
5 in
M16 × 2.5; 24 deep
30 O
K
1
, K
2
Flushing port DIN 3852
5)
M48 × 2; 22 deep 2 X
T Fluid drain DIN 3852
5)
M48 × 2; 22 deep 2 X
M
B
Measuring pressure B DIN 3852
5)
M18 × 1.5; 12 deep 400 X
M
S
Measuring pressure S DIN 3852
5)
M18 × 1.5; 12 deep 30 X
R(L) Fluid filling and air bleeding
(drain port)
DIN 3852
5)
M48 × 2; 22 deep 2 O
U Flushing port DIN 3852
5)
M18 × 1.5; 12 deep 5 X
7)
M
1
, M
2
Control pressure measuring DIN 3852
5)
see datasheetof
controlunits
400 X
1) Center bore according to DIN332
2) Thread according toDIN13
3) Observe the instructions in Part I (product-specific and general
instructions) concerning the maximum tightening torques.
4) Depending onthe application, momentary pressure peaks can occur.
Keep this inmind when selecting measuring devices and fittings.
5) The countersink may bedeeper than specified inthe standard.
6) Metric fastening thread isadeviation from standard.
7) For above-reservoir installation and for all installation positions
with "drive shaft up" a bearing flushing must be installed.
8) Plugged and high-pressure-proof with flange plate. Depending on
application, B and/or B
1
must be connected. The unused port
mustbe plugged with a flange plate.
9) O=Must beconnected (comes plugged)
X=Plugged (in normal operation)