66/72 Troubleshooting
BoschRexrothAG, axial piston variable pump A4VSO, RE 92050-01-X-B1/2019.08.23
14 Troubleshooting
Table 18 isintended tosupport troubleshooting. This table isnot exhaustive.
Issues may occur inpractice that are not listed here.
14.1 How toproceed for troubleshooting
▶ Use asystematic and targeted approach, even when pressed for time. Random,
indiscriminate removal and changing ofsettings could make itimpossible
todetermine theoriginal cause ofthefault.
▶ First get ageneral idea ofhow your product works inconjunction with
theentiresystem.
▶ Try tofind out whether ornot theproduct was working properly inconjunction
with theentire system before thefault occurred.
▶ Try todetermine any changes tothe entire system inwhich theproduct
isinstalled:
–Have there been any changes tothe application conditions oroperating range
oftheproduct?
–Has maintenance work recently been carried out? Is there aninspection
ormaintenance log?
–Have any changes (e.g. upgrades) orrepairs been made tothe overall system
(machine/system, electrics, control) ortothe product? If yes: What changes?
–Has thehydraulic fluid been changed?
–Has theproduct ormachine been used asintended?
–How does themalfunction appear?
▶ Try toget aclear idea ofthecause ofthefault. Directly ask the(machine)
operator.
▶ Document thework carried out.
▶ If faults cannot be rectified, contact BoschRexrothService; for the address,