52/72 Commissioning
BoschRexrothAG, axial piston variable pump A4VSO, RE 92050-01-X-B1/2019.08.23
8.3 Recommissioning after standstill
Depending onthe installation conditions and ambient conditions, changes may
occurinthe hydraulic system which make recommissioning necessary.
The following criteria may make recommissioning necessary:
• After a period of standstill longer than 1hour (to ensure fluid immersion especially
with above-reservoir installation)
• Air and/or water inthe hydraulic system
• Old hydraulic fluid
• Other contamination
▶ Before recommissioning, proceed asdescribed inchapter8.1 "Initial
commissioning" onpage47.