BoschRexrothAG, RE 92050-01-X-B2/2019-08-23
16 A4VSO Series 10, 11 and 30 | Axial piston variable pump
Dimensions, size 40
Dimensions [mm]
▼ Cyl. shaft with shaft key (DIN6885) ▼ Splined shaft (DIN5480)
P ‒ AS10 × 8 × 56 Z ‒ W32 × 2 × 14 × 9g
1.5
22
58
56
68
ø32
M10
1)2)3)
-0.2
+0.018
+0.002
Shaft key width10
M10 x 1.5
1) 2)
46
7.5
22
28
ø40
Ports Standard Size
3)
p
max abs
[bar]
4)
State
9)
B Working port (high-pressure series)
Fastening thread
SAE J518
6)
DIN 13
3/4in
M10 × 1.5; 17 deep
400 O
B1 2. Working port (high-pressure series)
Fastening thread
SAE J518
6)
DIN 13
3/4in
M10 × 1.5; 17 deep
400 X
8)
S Suction port
Fastening thread
SAE J518
6)
DIN 13
1 1/2 in
M12 × 1.75; 20 deep
30 O
K
1
, K
2
Flushing port DIN 3852
5)
M22 × 1.5; 14 deep 2 X
T Fluid drain DIN 3852
5)
M22 × 1.5; 14 deep 2 X
M
B
Measuring pressure B DIN 3852
5)
M14 × 1.5; 12 deep 400 X
M
S
Measuring pressure S DIN 3852
5)
M14 × 1.5; 12 deep 30 X
R(L) Fluid filling and air bleeding
(drain port)
DIN 3852
5)
M22 × 1.5; 12 deep 2 O
U Flushing port DIN 3852
5)
M14 × 1.5; 11.5 deep 5 X
7)
1) Center bore according to DIN332
2) Thread according toDIN13
3) Observe the instructions in Part I (product-specific and general
instructions) concerning the maximum tightening torques.
4) Depending onthe application, momentary pressure peaks can occur.
Keep this inmind when selecting measuring devices and fittings.
5) The countersink may bedeeper than specified inthe standard.
6) Metric fastening thread isadeviation from standard.
7) For above-reservoir installation and for all installation positions
with "drive shaft up" a bearing flushing must be installed.
8) Plugged and high-pressure-proof with flange plate. Depending on
application, B and/or B
1
must be connected. The unused port
mustbe plugged with a flange plate.
9) O=Must beconnected (comes plugged)