EasyManua.ls Logo

Bosch Therm 6000 S - Reset Button; Locked Condition; Installation Instructions

Bosch Therm 6000 S
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 720 800 095 (2014/05) Therm 6000S
14 | Installation instructions
4.11 Reset button
If the LCD shows the error symbol do not shut o power
or unplug the heater. Follow instructions below to reset error
rst.
Record the error code on LCD and consult chapter 10 to
identify the error.
Fig. 18 Error code
After following instructions indicated in “Troubleshooting”
section,
press reset button rmly in order to return heater to normal
operation.
Fig. 19 Reset button
If the problem persists, contact your installer.
4.12 Locked condition
This condition is only valid for appliances with one or more
remote controls installed.
Fig. 20 Locked condition
Whenever LCD shows the temperature setting cannot
be adjusted because the appliance is in use by a user which
already
selected a dierent temperature. Appliance will be
automatically unlock 5 minutes after closing hot water tap.
5 Installation instructions
This appliance has a error codes system. The
visualization of these codes is made through
the LCD display. (Fig. 4, [4]).
DANGER: Explosion!
Always close the gas valve before doing
any work in gas components.
The installation, the electric connection, the
gas installation, the installation of the
exhaustion / admission conducts, as well as
the start up must be carried out by a qualied
technician.
The appliance can only be used in the
countries mentioned in the type plate.
CAUTION:
Do not install the appliance where the
inlet water temperature is superior to
60 °C. In such cases we recommended
the installation of a mixer's valve in the
entrance of the appliance as prevention
measure.
6720608920-33.1AL

Table of Contents

Related product manuals