8 Installation instructions
8.1 Factory regulations
Natural gas
Heaters designed for Natural gas H (G 20) are factory sealed for
delivery after the values on the characteristics panel have been
checked.
Liquid gas
Butane heaters (G30) are factory sealed for delivery after the
values on the characteristics panel have been checked.
8.2 Measuring gas pressure
Conrm gas pressure after installation.
Connecting manometer
Shut o gas supply.
Remove the front cover Fig. 23 .
Loosen screw inside left test point tting (do not remove)
and connect manometer tube to test point.
Fig. 41 Gas pressure test port (left tapping)
Static Pressure Test
Turn gas supply back on.
Record static gas pressure reading in Table 7 .
Operating Pressure Test
Press ON/OFF button
to turn o the appliance.
Sealed parts must not be interfered with.
Heaters should not be ignited when the
connections pressure is less than 1,5 kPa
more than 2,5 kPa.
DANGER:
The following operations must be
carried out by a qualied technician.
Static Gas Pressure Reading
Pressure: ___________________ Date: ___________
Operating Gas Pressure Reading
Pressure: ___________________ Date: ___________
Table 7