5.6 Water connection
Mark the hot and cold water pipes in order to avoid
confusion.
Fig. 25
[1] Hot water
[2] Cold water
Make the hot and cold water connection.
In order to prevent problems caused by sudden inlet
pressure changes, the inclusion of an anti-return valve is
advised when installing the appliance.
5.7 Gas connection
The gas connection must full local regulations.
When the installation is eected with non-metallic, exible
tubes for use with bottled Butane, the following should be
observed:
• the tubes should be as short as possible and no longer than
1.5 m;
• the tube should be to IPQ ET 1038 standard and full all
applicable regulations;
• it should be accessible for inspection along its entire length;
• it should not be located near heat sources;
• bends and other obstructions should be avoided;
• the ends should be secured with adequate accessories and
clamps;
Tubes must be replaced every four years or whenever it
becomes dry or brittle;
Ensure that the inlet tube is clean;
Use the tube support accessory (provided) and an
appropriate clamp to make the gas inlet connections to the
appliance;
Install a gas shut-o tap as near to the appliance as possible;
When the gas inlet is connected to the main, metallic tubes
must be used according to the applicable regulations.
– The accessory provided must be used to connect the
heater to the gas main.
– Tighten the threaded head on the gas inlet (Fig. 26, [1])
and use the copper (Fig. 26, [2]) extremity to solder the
pipe to the main (Fig. 26, [3]).
Fig. 26
[1] Gas piping
For ease of installation it is recommended
that the water be connected followed by the
rest of the connections.
DANGER:
If local regulations are not follow exactly,
a re or explosion may result causing
property damage, personal injury or loss
of life.
Only use accessories recommended in this
manual.