6 720 800 095 (2014/05)Therm 6000S
Installation instructions | 15
5.1 Important remarks
Before installation, consult the gas company and current
legislation regarding gas appliance and site ventilation.
Install a gas shut-otap as close to the appliance as
possible.
After connection to the gas main, the appliance should be
carefully cleaned and tested for leaks; To avoid damage
from excess pressure in the valve gas regulator, this should
be carried out with the gas valve shut.
Ensure that the appliance installed is suitable for the type of
gas provided.
Ensure that the ow and pressures for the regulator installed
are those indicated for the consumption of the appliance
(see technical data in Table 4).
A low-pressure gas regulator must be installed with the
ap
pliance.
5.2 Selection of location for installation
Considerations relevant to location
Full requirements specic to each country.
The heater must not installed above a source of heat.
Respect the minimum installation measurements indicated
in Fig. 21.
The appliance must not be installed in sites where the
ambient temperature is susceptible to drop below 0 °C.
Where there is a risk of freezing, disconnect and empty the
appliance (chapter 4.10).
Assure that exists a socket for the electric connection at the
place were the appliance will be installed.
Assure that exists at the place of the installation a sewer
point for the condensed waters.
Combustion air
The air admission grill must be located in a well ventilated
area.
To avoid corrosion, products such as solvents, inks,
inammable gases, glue or domestic deterge
nts containing
halogenic hydro-carbons or any product that might provoke
corrosion must not be stored near the air admission grill.
Where these conditions are impossible to full, an alternative
site for gas admission and exhaust must be selected.
Surface Temperature
The maximum surface temperature of the appliance is below
85 °C. Special protection measures are not required for
inammable building materials or housings.
5.3 Minimum distances
Determine the installation site with the following limitations in
mind:
Maximum seclusion of all salient parts such as hoses and
pipes, etc.
Ensure adequate access for maintenance work, respecting
the minimum distances indicated in Fig. 21.
Fig. 21 Minimum distances
[A] Front > 2 cm, Side > 1 cm
5.4 Installation of xing bracket
Fix the xing bracket to the installation point selected.
Mark the position of the holes for the xing bracket, make
sure that the xing bracket is level, only then open the holes.
If the above conditions are not possible, it´s
mandatory to use the kit anti-freeze 7 709
003 709.
Before installing the xing bracket, ensure
that the water/gas/exhaust connections are
guaranteed.
A
A
6720608913-04.1AL