20 | Admission / exhaustion accessories (accessory Ø 80/80 mm)
6.2 Fitting instructions
• The permissible maximum ue/air pipe length, Lmax, for the
various possible ue congurations is specied in the tables
starting on chapter 8.6.
• If the concentric ue/air pipe enters a chimney below
ground level, the appliance may register a fault and shut
down in cold weather due to ice formation. For that reason
such ue congurations should be avoided.
6.3 Explanation of Symbols on Fitting Diagrams
Lightly grease seal on ue side with solvent-free
grease (e.g. Vaseline) (Fig. 29).
Push ue kit fully home (in this
case: 50 mm
insertion depth) (Fig. 30).
Drill two 3-mm diameter holes in the combus-
tion air pipe. Maximum drilling depth 8 mm. It is
essential that ue pipe is not damaged!
Fig. 31).
Secure joint with the screws supplied (Fig. 32).
Fig. 29
Fig. 30
Fig. 31
Fig. 32
50
2x
Ø 3mm
2x
360°
6 720 604 873-17.1O
50
50
6 720 604 873-18.1O
Ø 3mm
Ø 3mm
2x
Ø 3mm
6 720 604 873-21.1O
2x
6 720 604 873-22.1O