6 720 800 095 (2014/05)Therm 6000S
Installation instructions | 29
Repeat steps 1 and 2 as necessary until CO
2
values are
within the specied ranges.
As soon as the levels of CO
2
are correct, verify the values of
CO corresponds to the limits of the Table 10 . If the values
exceed the limits, it is necessary to verify the ventilation
system and heat exchanger.
End of adjustments
Record the nal values in Table 11 .
Reassemble all parts in reverse order:
Return slotted screw cover to original position and tighten
the philips screw, Fig. 45.
Reinstall Torx protection cover, Fig. 46.
Remove CO
2
analyser probe and reinstall athead screw
with gasket in exhaust collar.
Press ON/OFF button to turn OFF the heater.
Press ON/OFF button to turn ON the heater.
Heater is ready for
normal operation.
CO
2
range (%)
Máx. CO level
(measured)
Natural gas
Max. input P1 from 7.3% to 7.9% < 250 ppm
Min. input P2 from 2.7% to 3.1% < 60 ppm
Butane
Max. input P1 from 8.6% to 9.2% < 250 ppm
Min. input P2 from 3.0% to 3.4% < 60 ppm
Note: Values above are for climate controlled conditions.
Inputs such as gas pressure, heating value of the gas,
humidity and temperature of combustion air all impact CO
and CO
2
values. Changes in these inputs can result in
dierent CO and CO
2
values on the same appliance.
Table 10 CO
2
& CO target numbers
Program CO
2
values measured Date
P1 ______________ %
P2 ______________ %
Table 11