User Lockout:
The User Lockout feature is available to prevent
others from tampering with the EQs and associat-
ed parameters that have been set.
To access the User Lockout feature, press the
UTILITY button, then press the Arrow UP/Arrow
DOWN button until you see the following display:
Toggle the Encoder to select ON.
When set to ON, the User Lockout feature locks
the current preset and prevents users from access-
ing the following buttons and their associated para-
meters:
PRESET
DELAY
LIMITER
UTILITY
Pressing any of these buttons or turning the
Encoder wheel will yield the following message on
the display:
To Disable User Lockout:
Press and hold the UTILITY button for five
seconds until you see the following display:
User Lockout is now disabled.
28
8.1 UTILITY Button – User Lockout
Lockout:
Off
> Lockout: <
> No Access <
> Lockout <
On
> Lockout <
> Unlocked <