ENGLISH 31 / 77 CAP. 6 - TECHNICAL FEATURES
M
ULTIGAS
System pressure diagnostics Manual and automatic
Identifier for R-1234yf Optional (requires preliminary conversion to
refrigerant R-1234yf)
Alarms
Dryer filter replacement control Active
Vacuum pump oil replacement control Active
Full/empty vessel check Active
Full oil container control Visual
Empty oil container control Visual
Overall dimensions
WxDxH 600x522x1145 mm
Loadless weight about 85 kg
Power supply
Frequency 50 Hz
Voltage 230 V ~
Power 800 W
Environmental conditions
Operating temperature 5-40°C
Storage temperature and humidity -25 - +50°C, 10-90% R.H. (non condensing)
Ambient pressure 75 kPa ÷ 106 kPa
Max operating altitude 2000 m
Pollution degree 2
Overvoltage category II
Fuses Retarder fuses 250V T10A