CAP. 9 - SETUP 38 / 77 ENGLISH
M
ULTIGAS 8500 PLUS
CAP. 9 - SETUP
From the SETUP menu it is possible to select parameters and activations before starting cycles:
HYBRID FUNCTION
by selecting this entry, one may change the type of Oil to inject into the A/C system.
Attention: the HYBRID KIT PRO (optional accessory) is required in order to run this function
ECO LOC
by selecting this entry, you can enable the ECO LOCK® function (the ECO LOCK® quick
coupler must be present on the car).
RECHARGE MODE
by selecting this entry, one may decide whether to enable use of the Quick Mode or Zero
Tolerance recharge method
PRESSURE CHECK
by selecting this entry, one can enable or disable the pressure check.
AIR PURGE SYSTEM
by selecting this entry, one can enable or disable the AIR PURGE SYSTEM function. If
enabled, on a weekly basis, the station, when switched on, will suggest the user to run the
procedure . If disabled, execution of the procedure will no longer be suggested.
MULTIPASS
by selecting this entry, one may decide whether or not to enable the multipass function,
which enables an additional recycling, within the station itself, started in automatic when it is
switched on but not in use. This function ensures a higher level of purity of the recycled
refrigerant to the advantage of the service quality.
RECOVERED GAS AND OIL PRINTING
selecting this entry, you can choose whether you want to enable displaying and printing of
the recovered gas quantity.
REPORTS SAVING MODE
by selecting this entry, you can save the reports of the performed charges (automatic cycles or
Reg. 842/2006).
REPORT DATA
select what data you would like to include in the saved and printed report:
-license plate
-km
-client’s name
-technician’s name
HOSES LENGTH
by selecting this entry, it will be possible to change the length of the charge hoses.
UNIT OF MEASURE
selecting this entry, you can modify the pressure unit of measurement (switching from Bar to
PSI)