67XXU USB/Serial Scale Service Manual 67
Command: U<CR> (55h 0dh)
Command: u<CR> (75h 0dh)
Command: A<CR> (41h 0dh)
Command: m<CR> (6dh 0dh)
Response
Changes units of measure (simulate UNIT key) and return scale status with new units.
The new measure unit should be allowed to use
<LF> U
1
U
2
U
3
U
4
U
5
<CR><LF> S H
1
H
2
H
3
H
4
<CR><ETX>
Response
Returns current units-of-measure as a single numeric character.
<LF>x<CR><ETX>
x =
1 = grams
2 = kilograms
3 = ounces
4 = pounds
5 = pounds - ounces
Response
Returns scale OPOS capabilities as a string of five flag characters.
<LF>vwxyz<CR><ETX>
v = T - scale has a weight display (CapDisplay)
v = F - scale does not have a weight display
w = T -scale has a text display (CapDisplayText)
w = F -scale does not have a text display
x = T -scale can calculate unit price (CapPriceCalculating)
x = F -scale cannot calculate unit price
y = T -scale allows setting tare value (CapTareWeight)
y = F -scale does not allow setting tare value
z = T -scale may be zeroed (CapZeroScale)
z = F -scale cannot be zeroed
Response
Returns current maximum weight supported by the scale as a string value,
without decimal point and in the currently enabled unit of measure.
<LF>XX<CR><ETX>