68 67XXU USB/Serial Scale Service Manual
Command: <ENQ><CR> (05h 0dh)
Command: all others
Table 7.4 Summary of Command and Response:
Response
Depends on the scale and protocol.
<LF>OPOS<CR><ETX>
OPOS - enabled scale
Response
Unrecognized command
<LF>? <CR><ETX>
Command Response
ASCII HEX
W<CR> 57 0d Read scale weight:
<LF>^^^^^^^^U
1
U
2
U
3
U
4
U
5
<CR><LF>S H
1
H
2
H
3
H
4
<CR><ETX>---over capacity
<LF>________U
1
U
2
U
3
U
4
U
5
<CR><LF>S H
1
H
2
H
3
H
4
<CR><ETX>---under capacity
<LF>-------- U
1
U
2
U
3
U
4
U
5
<CR><LF> S H
1
H
2
H
3
H
4
<CR><ETX>---zero-point error
<LF><P>W
1
W
2
W
3
W
4
W
5
<DP>W
6
U
1
U
2
U
3
U
4
U
5
<CR><LF> S H
1
H
2
H
3
H
4
<CR><ETX>---normal data
S<CR> 53 0d <LF> S H
1
H
2
H
3
H
4
<CR><ETX>; read scale status
Z<CR> 5a 0d <LF> S H
1
H
2
H
3
H
4
<CR><ETX>; simulate ZERO key
U<CR> 55 0d <LF>U
1
U
2
U
3
U
4
U
5
<CR><LF> S H
1
H
2
H
3
H
4
<CR><ETX>; simulate UNIT key
u<CR> 75 0d <LF> x<CR><ETX>
A<CR> 41 0d <LF>vwxyz<CR><ETX>
m<CR> 6d 0d <LF>xx<CR><ETX>
<ENQ><CR> 05 0d <LF>OPOS<CR><ETX>
L<CR> 4c 0d <LF>H
1
H
2
H
3
H
4
<CR><ETX>; simulate HOLD key
X<CR> 58 0d Power off the scale, simulate OFF key
others <LF>? <CR><ETX>