Brocade FastIron, FCX, ICX, and TurboIron Diagnostic Reference 95
53-1002965-01
IPv6 MLD debug commands
5
MLD: rcvd Report-V1(ty=131) g=2001:DB8::25:2503 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/22), mld_size=24
debug ipv6 mld prime-port ethernet
Syntax: [no] debug ipv6 mld prime-port ethernet stackid/slot/port
This command enables the activity of the physical port and primary port if trunking happened. The
stackid/slot/port variable refers to the stack ID, slot number, and port number of a specific
Ethernet port.
Brocade# debug ipv6 mld prime-port ethernet 1/1/21
Brocade# debug ipv6 mld show
debug ip6 mld prime-port 1/1/21 is enabled
Brocade# MLD: rcvd Leave(ty=132) g=2001:DB8::24:2400 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/22), mld_size=24
MLD send Query(t=130) V1, s=fe80::21b:f3ff:fe84:124 2001:DB8::24:2400 to
VL510(ethe 1/1/22 ) rsp=10000 mld=24B, pkt=86B
MLD: rcvd Leave(ty=132) g=2001:DB8::24:2401 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/21), mld_size=24
MLD send Query(t=130) V1, s=fe80::21b:f3ff:fe84:124 2001:DB8::24:2401 to
VL510(ethe 1/1/21 ) rsp=10000 mld=24B, pkt=86B
MLD: rcvd Leave(ty=132) g=2001:DB8::24:2402 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/22), mld_size=24
MLD send Query(t=130) V1, s=fe80::21b:f3ff:fe84:124 2001:DB8::24:2402 to
VL510(ethe 1/1/22 ) rsp=10000 mld=24B, pkt=86B
MLD: rcvd Leave(ty=132) g=2001:DB8::24:2403 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/21), mld_size=24
MLD send Query(t=130) V1, s=fe80::21b:f3ff:fe84:124 2001:DB8::24:2403 to
VL510(ethe 1/1/21 ) rsp=10000 mld=24B, pkt=86B
MLD: rcvd Leave(ty=132) g=2001:DB8::24:2404 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/22), mld_size=24
MLD send Query(t=130) V1, s=fe80::21b:f3ff:fe84:124 2001:DB8::24:2404 to
VL510(ethe 1/1/22 ) rsp=10000 mld=24B, pkt=86B
MLD: rcvd Leave(ty=132) g=2001:DB8::25:2500 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/21), mld_size=24
MLD send Query(t=130) V1, s=fe80::21b:f3ff:fe84:124 2001:DB8::25:2500 to
VL510(ethe 1/1/21 ) rsp=10000 mld=24B, pkt=86B
MLD: rcvd Leave(ty=132) g=2001:DB8::25:2501 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/22), mld_size=24
MLD send Query(t=130) V1, s=fe80::21b:f3ff:fe84:124 2001:DB8::25:2501 to
VL510(ethe 1/1/22 ) rsp=10000 mld=24B, pkt=86B
MLD: rcvd Leave(ty=132) g=2001:DB8::25:2502 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/21), mld_size=24
MLD send Query(t=130) V1, s=fe80::21b:f3ff:fe84:124 2001:DB8::25:2502 to
VL510(ethe 1/1/21 ) rsp=10000 mld=24B, pkt=86B
MLD: rcvd Leave(ty=132) g=2001:DB8::25:2503 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/22), mld_size=24
MLD send Query(t=130) V1, s=fe80::21b:f3ff:fe84:124 2001:DB8::25:2503 to
VL510(ethe 1/1/22 ) rsp=10000 mld=24B, pkt=86B
MLD: rcvd Leave(ty=132) g=2001:DB8::25:2504 resp=0, pkt
S=fe80::200:bff:fe82:50f5, on VL510 (phy 1/1/21), mld_size=24
debug ipv6 mld protocol
Syntax: [no] debug ipv6 mld protocol [query | report]
query - Displays debugging information about the IPv6 MLD queries transmitted and received.
report - Displays debugging information about the IPv6 MLD reports transmitted and received.

Table of Contents

Other manuals for Brocade Communications Systems FastIron X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron X Series and is the answer not in the manual?

Brocade Communications Systems FastIron X Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron X Series
CategorySwitch
LanguageEnglish

Related product manuals