52 Brocade FastIron, FCX, ICX, and TurboIron Diagnostic Reference
53-1002965-01
debug pp-bum-trunk-hash
3
Brocade# debug pp-bum-trunk-hash 1/1/11 3 0000.00aa.aaaa 0000.00bb.1111 ipv6 128
2001:DB8::1:1 2001:DB8::1:1 10 10 1 100
Designated Trunk Port = 1/1/4
For the non-IP BUM flow, the command output resembles the following example.
Brocade# debug pp-bum-trunk-hash 1/1/1 3 0000.00aa.aaaa 0000.00bb.1111 non-ip
Designated Trunk Port = 1/1/5