There are two ways to configure the time when a data log is recorded. The Log Time feature allows up to
4 data logs to be recorded each day, at specific times. The Log Interval feature allows a data log to be
recorded each time a time interval has passed.
Only the Log Time or Log Interval may be active at once. While one type of data logging has been
enabled, the other menu will be inaccessible.
Log Time Setup (LOGTIME)
The Log Time menu contains four log points (LOG 1 to LOG 4). Each log time is configured separately.
For each daily log time desired, enable a log, and set the log time for the hours and minutes the log is to
be recorded. The time is set in real-time, based on the real time clock setup.
The Log Time feature will roll-over, deleting the oldest data logs (in blocks of 8) when the log is full and
new logs must be recorded. This makes it the most useful for long-term data logging.
Interval Setup (INTERVL)
The Interval menu sets the time interval for data logging. Every time interval, one data point will be
recorded. To enable interval data logging, enable the feature, and set the interval time for the hours and
minutes between each log.
The Log Interval feature will not delete old data, and data logging will stop when the log is full. This makes
it the most useful for short periods and logging specific functions.