6. Replacing Parts
Replacement & Assembling
1. The Sen
sor (3) is to be replaced. Make sure that the claws (4) of the Sensor are properly hooked.
Entry of the Connector
3
4
2
1
3
4
2. Fix the Pump Senso
r Holder by the two Screws (2) with tightening torque 1.5 N·m.
3. Connect the Connector (1).
Reconfirmation
1. Turn ON the printer.
2. Select [ Maintenance Unit ] in the Advanced Menu. (Refer to “3-1-3. How to go to Advanced Menu” and
“3-1-5-4. Input Check”.)
3. Confirm that the display shows ON/OFF by turning the Pump Rotor Gear.
(There is a hole in the circumferential of the Pump Rotor Gear; the sensor is ON at the hole.)
4. Turn OFF the printer after the initial operation is confirmed.
5. Attach the Covers. (Refer to “6-1-2. Assembling/Disassembling of the Covers”.)
GT-3 Series