6. Replacing Parts
3.
Fix the Cap Sensor Holde
r with the Screw, with tightening torque 1.5 N·m.
4. Mount the Maintenance Unit. (Refer to “6-1-16. Assembling / Disassembling of the Maintenance Unit”. )
5. Confirm the initial operation, which is OK with no errors occur.
Hint: How to replace with the Maintenance Unit mounted on the printer
Requir
e
d Tools
・Phillips screwdriver of 70mm long
1. Turn OFF the printer.
2. Remove the Screw (2) that fixes the Maintenance Cover (1).
(1)
(2)
3. Remove the
Screw (4) that fixes the Cap Sensor Holder (3).
(3)
(4)
4. Remov
e the Connector.
5. Replace to the new Sensor and connect the Connector. Make sure that the all the claws of the sensor
are properly hooked.
6. Fix the Cap Sensor Holder (3) with the Screw (4) with tightening torque 1.5 N·m.
7. Mount the Maintenance Cover (1) with the Screw (2) with tightening torque 0.5 N·m.
GT-3 Series
195