3-118
Confidential
9.34 Panel PCB ASSY
■ A4 model
(1) Disconnect the Connector (CN2) and Flat cable (CN3) from the Panel PCB ASSY.
Fig. 3-160
(2) Release the ten Hooks to remove the Panel PCB ASSY from the Panel unit.
Fig. 3-161
Note:
The Panel PCB ASSY consists of two PCBs, and they are connected with a Flat cable.
Be sure to remove the two PCBs at the same time because the Flat cable might get
broken if you remove the PCBs.
Panel PCB ASSY
Connector
CN2
CN3
Flat cable
Lock
Flat cable
Panel PCB ASSY
Hook
Panel unit
Hook
Hook
Hook
Hook
Hook