EasyManua.ls Logo

Brother MFC-9465CDN - Switching of Timing to Execute Auto Registration

Brother MFC-9465CDN
590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-32
Confidential
Switching of timing to execute Auto Registration
<Function>
Relative displacement between Cyan, Magenta, Yellow, and Black is detected using the
registration mark sensor, and the Auto Registration is executed at the timing when the
displacement value exceeds the stipulated threshold value.
This is a function to switch the threshold value which is used as the timing to execute Auto
Registration.
The threshold value can be switched in three phases between High, Mid, and Low.
“*” is displayed at the end of the currently specified function in the LCD display.
<Operating procedure>
(1) Press the 4 and 5 buttons in this order in the initial state of the maintenance mode.
The "USBNo." will appear on the LCD.
(2) Press the or button to display "Regi Freq" and then press the OK or Start/Black
button.
(3) Select "Regi Freq = Mid", "Regi Freq = High", or "Regi Freq = Low" by pressing
the or button, and press the OK or Start/Black button.
(4) "Accepted" is displayed on the LCD, and the product goes back to the initial state of the
maintenance mode.
LCD Description
Regi Freq=Mid The frequency to execute Auto Registration is middle. (default)
Regi Freq=High The frequency to execute Auto Registration is high.
Regi Freq=Low The frequency to execute Auto Registration is low.
Note:
It can be set regardless of the Auto Registration switching function in the function
menu. Even if this function is switched, it does not affect the timing to execute Auto
Registration in the function menu.