272
MIDSECTION
EXHAUST HOUSING SERVICE
Install a new inne r exha ust ho using sea l. Apply
Adhesive 847 to the seal groove.
Clean and degrea se the adapte r housing and
outer exhaust h ousing mating surfaces with
Cleaning Solvent. Apply Gel-Seal II sealant to the
adapter flange of the exhaust housing.
Place the adapte r/inner exha ust housing into the
exhaust housing. Align the water tube.
Loosely inst all the small r etaining screws, n uts,
and washers.
Lubricate the upp er mount with so apy water a nd
push into place in the adapter housing. The mount
radius must face af t with the “T OP” mark facing
up.
Apply Locquic Primer and Nut Lock to the upp er
mount plate screws and inst all the plate a nd
screws loosely. In stall th e g round lead a nd star
washer under the forward starboard screw.
Align the oute r exhaust housing an d adapter by
placing two powerhe ad mounting screws through
their holes.
Install fou r mount plate screws and washers a nd
tighten t o a to rque o f 22 to 24 f t. lbs. (30 to 33
N·m).
13640
13692
32580
1. Powerhead mounting screws 13689
13690