Electrical system – 5000
Diagnostic and troubleshooting
Order number Date Valid from serial number T-code
226057-040 2005-09-23 914369- 675
© BT Europe AB Service Manual LWE130 12- 31
• Refer to Table 11, “List of error codes,” on page 32.
NOTE!
The status LED is continuously on while the hand terminal is connect-
ed.
Error code history
To check the error code history log carry out the following:
With the hand terminal connected as described in previous section...
Navigate to the ALARM menu.
The log will display up to 5 most recent error types with the following
information for each error.
A - Error code description.
B - Hour meter value when fault occurred.
C - Number of occurrences of specific error.
D - Transistor regulator temperature when fault occurred.
The error code history log can be optionally cleared when exiting the
ALARM menu.
*MAIN MENU*
PARAMETER CHANGE
* MAIN MENU *
STEER TABLE
* MAIN MENU *
PROGRAM VACC
SEM-X V..
24v 75A 00000
*MAIN MENU*
ALARMS
ENTER
ENTER
ROLL
ROLL
CODE
CODE
OUT
ENTER
00001 #01 20 C
CODE
CODE
OUT
OUT
ENTER
LOG BOOK CLEARED
G
PRESS OUT
OUT
Fig. 17 Menu tree for error code history display
* VFIELD NOT OK *
00015h #01 27°C
B
C
D
https://www.besttruckmanuals.com/