Electrical system – 5000
Parameters & adjustments
Order number Date Valid from serial number T-code
226057-040 2005-09-23 914369- 675
© BT Europe AB Service Manual LWE130 12- 41
From the truck to the hand terminal
To transfer a parameter set from the truck to the hand terminal use the
PARAMETER CHANGE function in the hand terminal:
• Connect the hand terminal. See “Connecting the hand terminal” on
page 27.
• Select SAVE PARAM from the menu and press ENTER.
• Press ROLL to select one of the 32 memory slots (Mod 00 to Mod
31).
Empty memory slots will display FREE. Memory slots which contain a
parameter set will display SEM-X
V.
• Press ENTER to save the truck’s parameter set.
NOTE!
It is advisable to keep a record of trucks and stored parameter sets.
This will help to ensure that saved parameter sets are restored to the
correct truck.
* MAIN MENU *
PARAMETER CHANGE
*MAIN MENU*
STEER TABLE
* MAIN MENU *
PROGRAM VACC
* MAIN MENU *
ALARMS
*MAIN MENU*
RESTOR PARAM.
SEM-X V..
24v 75A 00000
*MAIN MENU*
SAVE PARAM.
ENTER
ENTER
ROLL
ROLL
SELECT Mod 00
SELECT Mod 02
SELECT Mod 03
SELECT Mod 31
OUT
OVERWRITE DATA?
YES = ENTER NO = OUT
READING
Run all parameters
ENTER
ENTER
Memor
location
free
Memor
location
occupied
SEM -X V
SELECT Mod 01
FREE
ENTER