Electrical system – 5000
Functional description
Order number Date Valid from serial number T-code
226057-040 2005-09-23 914369- 675
© BT Europe AB Service Manual LWE130 12- 27
12.8.8 Hand terminal
General
It is necessary to have access to a hand terminal to perform the follow-
ing:
Modify parameters stored in the transistor regulator.
Upload or download parameter set-ups to/from the transistor regula-
tor.
Display error and diagnostic information.
Perform calibration.
Connecting the hand terminal
To connect the hand terminal:
Ensure the key switch is off [S17].
Fold out the main electrical panel. See section “12.4 Accessing main
electrical panel” .
Connect the hand terminal’s connector (Fig. 14 A) to the transistor
regulator’s diagnostic connector (Fig. 10 B).
Turn on the key switch [S17].
Hand terminal overview
The hand terminal consists of an alpha-numeric display (Fig. 15 A) and
six control buttons.
A
Fig. 14 Hand terminal
https://www.besttruckmanuals.com/