Electrical system – 5000
Parameters & adjustments
Order number Date Valid from serial number T-code
226057-040 2005-09-23 914369- 675
© BT Europe AB Service Manual LWE130 12- 43
If the response of the speed control is not balanced in both travel di-
rections.
If the VACC NOT OK error occurs.
When [R1] is removed or disturbed or is replaced.
Procedure
To perform calibration of the speed potentiometer use the PROGRAM
VACC function in the hand terminal:
Connect the hand terminal. See “Connecting the hand terminal” on
page 27.
Select PROGRAM VACC from the menu and press ENTER then
ENTER.
Move tiller arm to drive position.
Slowly move the speed control [L1] from neutral to full deflection first
in one direction then the other direction.
Press OUT followed by ENTER.
The transistor regulator and potentiometer have now been calibrated.
*MAIN MENU*
PARAMETER CHANGE
* MAIN MENU *
STEER TABLE
SEM-X V..
24v 75A 00000
* MAIN MENU *
PROGRAM VACC
ENTER
ENTER
ROLL
VACC SETTING
0.4 4.7
MIN VACC MAX
0.0 - 0.0
MIN VACC MAX
0.5 4.8
ARE YOU SURE ?
YES = ENTER NO = OUT
OUT
OUT
ENTER
Slowly move the speed control
towards max in both directions
ENTER
OUT
https://www.besttruckmanuals.com/