12-  38 Service Manual  LWE130 © BT Europe AB
Electrical system – 5000
Parameters & adjustments
T-code Valid from serial number Date Order number
675 914369- 2005-09-23 226057-040
12.10.3 List of parameters
NOTE!
Before changing any parameters, ensure you have read and under-
stood the procedures for viewing and setting parameters in the sec-
tions Adjusting parameters on page 37.
See also section Speed limitation on page 26 for information regarding 
the maximum speeds of the truck.
Table 13: Overview of parameters
Parameter 
name (display)
Function Min. Max. Std. Note
ACC.DELAY Determines accelera-
tion ramp time.
0 9 6
A= acceleration
DECELER.DELAY Determines decelera-
tion ramp when 
speed control is 
reduced.
0 9 5
D= deceleration
RELEASE BRAK-
ING
Determines neutral 
braking intensity.
0 9 5
B= braking intensity
INVERSION BRAK-
ING
Determines reverse 
braking intensity.
0 9 9
B= braking intensity
CUTBACK SPEED 
3
Determines truck’s 
max. speed.
0 9 9
S= maximum speed
CHECK UP DONE Resets service hours 
counter to zero.
- - OFF
CHECK UP TYPE Selects type of serv-
ice warning.
0 3 NONE
CHECK UP HOURS Determines “Time to 
next service”.
0 9 2
9:
:
A
9:
:
D
0:
:
0:
:
0:
:
S
https://www.besttruckmanuals.com/