Table 13: Overview of parameters
Parameter
name (display)
Function Min. Max. Std. Note
ACC.DELAY Determines accelera-
tion ramp time.
0 9 6
A= acceleration
DECELER.DELAY Determines decelera-
tion ramp when
speed control is
reduced.
0 9 5
D= deceleration
RELEASE BRAK-
ING
Determines neutral
braking intensity.
0 9 5
B= braking intensity
INVERSION BRAK-
ING
Determines reverse
braking intensity.
0 9 9
B= braking intensity
CUTBACK SPEED
3
Determines truck’s
max. speed.
0 9 9
S= maximum speed
CHECK UP DONE Resets service hours
counter to zero.
- - OFF
CHECK UP TYPE Selects type of serv-
ice warning.
0 3 NONE
CHECK UP HOURS Determines “Time to
next service”.
0 9 2
9: