Installation
Setting the parameters
© BT Repair manual  SWE100, 120, 120L, 120S, 140, 140L, 200D 4 –   7
Order no.. Date Valid from serial no. T code
258946-120 2012-08-30 6061850- 841×842×843
Programming PIN for resetting the truck
When the truck has stopped after a collision, the truck must be reset by 
entering a special PIN code. This PIN code must be programmed by a 
service technician at installation. 
The PIN that is activated is found in driver profile 1 and special block 
10. The PIN code has a standard value 0000, which must be changed 
to a chosen PIN code by a service technician.
Note! 
The PIN code must not contain the same number combination as any 
of the preprogrammed PIN codes.
4.4.2 Adjusting the parameters for the battery 
and battery charger
The following parameters must be adjusted or checked on battery 
installation.
Note!
Even if the battery comes with the truck from the factory, the 
parameters must be adjusted or checked.
Note! 
Ensure that service parameter 109 is set to the value of the battery 
fitted, and that the correct battery capacity has been set in parameter 
110.
Note! 
Only 134 Ah, 174 Ah and 201 Ah battery sizes may be used when 
using a Hawker Evolution battery. 
https://www.besttruckmanuals.com/