Functions and parameters
Parameters
© BT Repair manual  SWE100, 120, 120L, 120S, 140, 140L, 200D 6 –   19
Order no.. Date Valid from serial no. T code
258946-120 2012-08-30 6061850- 841×842×843
* Matrix for hardware/software compatibility
See the matrix below for the correct setting of factory parameter 1024. 
The setting depends on what version of transistor regulator the truck is 
fitted with.
• Value 0 = 1.5 kHz (default value)
• Value 1 = 8 kHz 
1023 Controls for 
hydraulic functions
1/4 1 1 1= The rear lifting and lowering 
control is connected to the second 
hydraulic function, while the front 
control is connected to the first 
hydraulic function.
2 = Rear lift and lowering control 
connected to the first hydraulic 
function and forward control 
connected to second hydraulic 
function.
3 = Both lifting and lowering 
controls are connected to the first 
hydraulic function. There are no 
other hydraulic functions.
4= The analogue lifting and 
lowering control is connected to the 
first hydraulic function, while the 
front control is connected to the 
second hydraulic function.
1024 Brake configuration
* see below
0/1 1 0 0= 1.5KHz braking frequency 
1= 8KHz braking frequency 
1101 Battery charger, on-
board
0/1 1 0 0 = No battery charger installed
1 = Battery charger installed
Transistor regulator Factory parameter 1024
Value = 0 Value = 1
243428/-001/-002 
246889/-001/-002 
246890/-001/-002
OK Not permitted
7513528-001/-newer 
7513526-001/-newer 
7513527-001/-newer
Not 
recommended
OK
Param
eter
Designation/
unit
Min./
Max.
Incr
eme
nt
Def
aul
t
Description