Commissioning
Logamatic EMS RC35 programming unit - Subject to technical modifications
18
5
5 Commissioning
5.1 General commissioning
Operation Result
1. Switch on the heating system.
While setting up the connection between the RC35 and EMS
or UBA1.x, the display shows the message on the right.
If the display shows a different message, look it up in
Chapter 10, page 48.
2. Set the language:
Open flap. Hold down and select the language with
rotary selector .
3. Set the date and time:
Hold down and set the flashing values with rotary
selector . Release button.
Hold down and set the flashing values with rotary
selector . Release button.
In the event of a power failure, the date and time are retained
for up to 8 hours. All other settings are saved.
4. Press + + simultaneously, to open the
SERVICE MENU.
Tab. 6 General commissioning
If necessary, you can change the contrast on the display:
B Hold down and and turn rotary selector at the same time.
RC35 version:
connect to:
connection setup ...
please wait
Open cover in order
to set language with
OK key.
language set:
English
SET DATE
set year
01.01.2000
SERVICE MENU
B
quick operation
settings
diagnosis
servicing