System settings (Service menu – Settings)
Logamatic EMS RC35 programming unit - Subject to technical modifications
36
6
6.4 DHW
B Turn rotary selector anti-clockwise until DHW is selected.
B Press to select domestic hot water.
Menu SETTINGS\DHW opens.
WARNING: Risk of scalding at the hot water draw-off points.
There is a risk of scalding at the hot water draw-off points if DHW temperatures can be
set above 60 °C and during thermal disinfection.
B Advise customers that they should only draw off mixed water.
Menu item Input range
Factory
setting Other information
Have you installed domestic
hot water?
yes, no no DHW cannot be uninstalled in
the case of boilers with DBA.
Limiting value for maximum
dom. hot water temp. setting:
60 °C to 80 °C 60 °C Subject to the boiler in use, a
the maximum possible set
DHW temperature is limited to
60 °C.
To which temperature should
your domestic hot water be
heated?
30 °C to 80 °C 60 °C If the limit has been set to
> 60 °C, this higher value can
also be selected in the “USER
MENU”.
What should be used for
domestic hot water heating?
3-way switching
valve, cylinder
primary pump
3-way
switching
valve
1)
Do you wish to change the
dom. hot water switching
programme?
yes, no no When selecting “yes” the
system jumps to the DHW
switching program.
Tab. 14 Navigator for service menu SETTINGS\DHW
SERVICE\SETTINGS
B
plant data
boiler data
domestic hot water
heating circuit 1