EasyManuals Logo

Buderus Logamatic EMS RC35 Installation And Service Instructions

Buderus Logamatic EMS RC35
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
System settings (Service menu – Settings)
Logamatic EMS RC35 programming unit - Subject to technical modifications
26
6
6.2 Boiler data
B Turn rotary selector anti-clockwise until boiler data is selected.
B Press to select boiler data.
The menu SETTINGS\BOILER is opened.
Menu item Input range
Factory
setting
Other information
Boiler pump after-run time
after burner stops?
deactivated,
1 to 60 min,
24 h
5 min Setting only possible with boilers with
internal pump.
1)
1) Not possible or not available with boilers with UBA1.x.
Set the pump logic
temperature:
0 to 65 °C 47 °C Setting only possible in conjunction
with BRM10.
Tab. 11 Navigator for service menu SETTINGS\BOILER
SERVICE\SETTINGS
B
plant data
boiler data
domestic hot water
heating circuit 1

Other manuals for Buderus Logamatic EMS RC35

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Buderus Logamatic EMS RC35 and is the answer not in the manual?

Buderus Logamatic EMS RC35 Specifications

General IconGeneral
BrandBuderus
ModelLogamatic EMS RC35
CategoryController
LanguageEnglish

Related product manuals