Chapter 4 Web Admin interface
LinkStation User Manual 136
Name
Descriptions
Storage
RAID Array *1
*1: LinkStation models with
multiple hard drives only
Congure RAID arrays from this menu. RAID 0 and RAID 1 modes are available.
If RAID is disabled, the drives in the LinkStation will be available as separate
drives.
[Disk Structure]:
To congure a RAID array, check the target drives, select a RAID mode, and
click [Create Raid Array]. To delete the RAID array, select [Delete RAID Array].
Warning: All data is lost when the RAID array is modied. Back up any
important data before changing RAID settings.
[RAID Array Error Detection Response]:
If shutdown is enabled, the LinkStation will automatically shut down when
a RAID 1 error is detected. RAID 0 arrays and drives in normal mode are not
aected by this setting.
The default setting is [Shutdown].
[RAID Array check speed]:
Select the RAID scanning speed from the following:
[High]: ~ 10 hours per TB
[Normal]: ~ 20 hours per TB
[Low]: ~ 100 hours per TB
RAID Scanning *1
*1: LinkStation models with
multiple hard drives only
A RAID scan tests your RAID array for errors. If errors are found, they are xed
automatically if possible. If you are using a RAID array, regular RAID scans are
recommended.
Recoverable errors found during standard le operations will be automatically
repaired regardless of whether RAID Scanning is enabled or not.
Status Examples
Recoverable errors Read errors in data or system area of a RAID 1
array
Unrecoverable errors Write errors, RAID management area errors,
partition errors, drive detection failure