The Info/Error LED blinks red to indicate an error.
The error may be identied by the pattern of blinking.
Note: The error may also be viewed from NAS Navigator2.
Error code Descriptions
E00 MPU is abnormal; no power. Contact Bualo tech support for assistance.
E01 DRAM data line is abnormal. Contact Bualo tech support for assistance.
E02 DRAM address line is abnormal. Contact Bualo tech support for assistance.
E03 RTC chip is abnormal. Contact Bualo tech support for assistance.
E04 Kernel extraction failed. Contact Bualo tech support for assistance.
E14 The RAID array cannot be mounted. Turn o power, then turn power on again.
If the same error is displayed, re-congure RAID. And if the same error is displayed again, contact
Bualo tech support for assistance.
E15 Hard drive I/O error. Contact Bualo tech support for assistance.
E16 The hard drive is not connected, or data transfer has failed. Check your hard drive status. If the error
still remains, contact Bualo tech support for assistance.
E17 Controller error. Contact Bualo tech support for assistance.
E21 Controller error. Contact Bualo tech support for assistance.
E23 The hard drive has crashed. Contact Bualo tech support for assistance.
Place Status
10s place The LED illuminates for 1 second every 0.3 seconds.
The number of ashes is the tens place of the error code.
1s place The LED illuminates for 0.5 seconds every 0.3 seconds.
The number of ashes is the ones place of the error code.
Power LED
Status Descriptions
Solid Blue The LinkStation is powered on.
Blinking blue The LinkStation is starting up or shutting down.
O The LinkStation is o.