3
Safety
MAINS VOLTAGE: TX5 V2 - TX600 V2 operate from an AC
power source between 110 and 240 V.
TX1000 V2 - TX2500 V2 operate from a power source be-
tween 220 and 240 V. WARNING: To avoid damage DO
NOT CONNECT TO 110V.
These power supplies use a C19 plug. The wiring format is:
Ground - GREEN/YELLOW
Neutral - BLUE
Live - BROWN
SWITCHED MODE POWER SUPPLY HAZARD Please note that the power supply units in this
equipment is of the switched mode variety and have lethal voltages present internally. The
switched mode supplies are universal input fully approved type. They are non serviceable
modules and should be fully replaced should they fail.
FUSES Only use fuses with the specified voltage and current ratings as stated on the back
panel. Failure to do so may increase the risk of equipment failure, shock and fire hazard.
R.F. The N type R.F. power output socket contains R.F. voltages which may burn or present
a shock. Please make sure that the equipment is connected to an adequately rated load or
antenna system while in operation.
TOXIC HAZARD This equipment includes R.F. components that may contain Beryllium oxide
which is a highly toxic substance that could be hazardous to health if inhaled or ingested.
Care should be taken when replacing or discarding such devices. Seek expert advice from
the manufacturer should you physically damage a device that contains Berillyium Oxide. The
main R.F. output power transistor contains Beryllium oxide.
OTHER SAFETY CONSIDERATIONS Do not operate this equipment in the presence of
flammable gases, fumes or liquids Do not expose this equipment to rain or water.
12