7.9 Parameters
This section contains a list of all the parameters in the unit and all of their possible values. This
should must be used as a reference when controlling the unit via text based access (Telnet
or Serial RS232) or the Web API.
When setting the value of a parameter, trying to set a value greater than the allowed maxi-
mum will result in the maximum value being set. When setting a value less than the allowed
minimum, the minimum value will be set. When setting a parameter to a value which does
not align to the step size of that particular parameter, the closest lower value multiple of the
step size will be set.
Setting values allows the use of prefixes. available prefixes are: m (mili = *0.001), k or K (kilo =
* 1000), M (Mega = * 1000). These can be used when setting a parameter value. E.g.:
Setting the frequency to 98 MHz:
”set transmitter.frequency 98M”
”set transmitter.frequency 98000K”
”set transmitter.frequency 98000000”
7.9.1 RF Settings
Frequency transmitter.frequency
Range: Frequency in Hz (87.5MHz to 108MHz for Normal Band II transmitters).
e.g.: ”set transmitter.frequency 90M”
or ”set transmitter.frequency 90000k”
or ”set transmitter.frequency 90000000”
Power transmitter.set_power
Range: Power in Watts (depending on the TX Model, see attached table)